OSHA guide · 1910.25
Mezzanine Stair Requirements: OSHA Angle, Rise, Tread and Rail Rules
OSHA sets standard mezzanine stairs at 30 to 50 degrees, with 9.5-inch maximum risers and 9.5-inch minimum treads. A flight with at least 3 treads and 4 risers also needs stair rails and handrails.

Which Rules Apply to Mezzanine Stairs in Fort Worth?
OSHA 1910.25 sets the stair rules that protect your employees, and the building code sets its own. Fort Worth builds to the 2021 International Building Code with local amendments. Plan review checks the stairs on your drawings against that code. Most numbers below are OSHA's, and we name the code each time. We design to the IBC and OSHA, and the stricter rule wins. See mezzanine stairs, railings and gates in Fort Worth.
What Angle Does OSHA Allow for Mezzanine Stairs?
Between 30 and 50 degrees from the horizontal for standard stairs. OSHA 1910.25(c)(1) says standard stairs are "installed at angles between 30 to 50 degrees from the horizontal." Steeper stairs are a different class with their own rules. Ship stairs and alternating tread stairs run at "50 to 70 degrees from the horizontal," per 1910.25(e)(1) and (f)(1).
| Stair type | Angle from horizontal | Section |
|---|---|---|
| Standard stairs | 30 to 50 degrees | 1910.25(c)(1) |
| Ship stairs | 50 to 70 degrees | 1910.25(e)(1) |
| Alternating tread stairs | 50 to 70 degrees | 1910.25(f)(1) |
A standard stair takes more floor space, but it is the easier climb with a load in hand. Ship stairs and alternating tread stairs save space. They suit tight spots and occasional trips, not routes people use all shift.
How Tall Can Mezzanine Stair Risers Be, and How Deep the Treads?
Risers can be 9.5 inches tall at most, and treads must be at least 9.5 inches deep. OSHA 1910.25(c)(2) sets a "maximum riser height of 9.5 inches (24 cm)." Section 1910.25(c)(3) sets a "minimum tread depth of 9.5 inches (24 cm)." The width rule is in 1910.25(c)(4): a "minimum width of 22 inches (56 cm) between vertical barriers."
Your deck height sets the riser count. We divide the height from floor to finished deck into risers of the same height. That keeps the top step from coming out short.
How Much Headroom and Landing Space Do Mezzanine Stairs Need?
At least 6 feet 8 inches of headroom, and landings at least 30 inches deep. OSHA 1910.25(b)(2) requires vertical clearance "above any stair tread to any overhead obstruction" of at least 6 feet, 8 inches. Section 1910.25(b)(4) says landings and platforms are "at least the width of the stair and at least 30 inches (76 cm) in depth."
Watch the deck beams, lights and sprinkler pipes above any stair that runs under part of the deck. A landing also lets a long run turn a corner, which helps where floor space is short.
When Do Mezzanine Stairs Need Handrails and Stair Rails?
When a flight has at least 3 treads and at least 4 risers. OSHA 1910.28(b)(11)(ii) says each such flight "is equipped with stair rail systems and handrails." A stair up to a mezzanine deck nearly always meets that count. The two parts do different jobs. The stair rail guards the open side, and the handrail gives a grip.
| Part | Rule | Section |
|---|---|---|
| Stair rail height | At least 42 inches, for stair rails installed on or after January 17, 2017 | 1910.29(f)(1)(ii)(B) |
| Handrail height | 30 to 38 inches, from each tread's leading edge | 1910.29(f)(1)(i) |
| Open landing edge 4 feet or more up | A guardrail or stair rail system | 1910.28(b)(11)(i) |
Because the heights differ, the handrail usually mounts below the top of the stair rail. Our OSHA guardrail guide covers the deck edge at the top of the stair.
How Strong Must a Mezzanine Stair Be?
Strong enough for five times the normal load, and at least 1,000 pounds at any point. OSHA 1910.25(b)(6) says "Each stair can support at least five times the normal anticipated live load." The same paragraph sets a concentrated load of at least 1,000 pounds applied at any point.
The building code sets its own number. IBC Table 1607.1 lists a minimum uniform live load of 100 psf for stairs and exits. We design to the IBC and OSHA, and the stricter rule wins. Your engineer checks both on the drawings. See Fort Worth mezzanine permits and code for how plan review works.
Can a Ladder Replace Stairs to Reach a Mezzanine?
Sometimes. A fixed ladder suits service access, while stairs suit daily foot traffic and carrying goods. Whether a ladder can serve as an exit is a building code question, and plan review decides. Where a ladder is used, OSHA 1910.23 sets its rules. Rungs are spaced "not less than 10 inches (25 cm) and not more than 14 inches (36 cm) apart," measured center to center.
- Clear width: at least 16 inches on fixed ladders, per 1910.23(b)(4).
- Side rails: on through or side-step ladders, at least 42 inches above the landing, per 1910.23(d)(4).
- Fixed ladders over 24 feet installed on or after November 19, 2018: a personal fall arrest system or a ladder safety system, per 1910.28(b)(9)(i)(B).
- The opening at the top: a self-closing gate or an offset rail, per 1910.29(b)(13).
By November 18, 2036, every fixed ladder covered by 1910.28(b)(9) needs one of those systems, per paragraph (b)(9)(i)(D). Our guide to catwalk and crossover bridge rules covers ladders and steep stairs at walkways.
Which Mezzanine Stair Builds Can You Choose From?
Welded, knockdown and modular stairs, with landings where the run turns. Welded stairs arrive in one piece and go in quickly on site. Knockdown stairs come apart for shipping, which lowers freight cost. Modular stairs ship in compact sections. Ship ladders and caged ladders suit service access to a work platform. We match the build to your deck height and floor space.
You buy the stair through us and our crew installs it with the rails and gates. One order, one crew, one point of contact.
Mezzanine Stair Questions, Answered
What is the steepest stair OSHA allows on a Fort Worth mezzanine?
A standard stair can be up to 50 degrees from the horizontal under OSHA 1910.25(c)(1). Ship stairs and alternating tread stairs can run from 50 to 70 degrees. The IBC also applies in Fort Worth, and plan review decides.
Source: OSHA 29 CFR 1910.25(c)(1), (e)(1) and (f)(1)
How wide must a mezzanine stair be in Fort Worth?
OSHA 1910.25(c)(4) sets a minimum width of 22 inches between vertical barriers. The building code has its own stair rules, and Fort Worth plan review checks them. We design to both, and the stricter rule wins.
Source: OSHA 29 CFR 1910.25(c)(4)
Does a short mezzanine stair in Fort Worth need a stair rail?
Under OSHA 1910.28(b)(11)(ii), a flight with at least 3 treads and 4 risers needs stair rail systems and handrails. Stair rails installed on or after January 17, 2017 stand at least 42 inches high.
Source: OSHA 29 CFR 1910.28(b)(11) and 1910.29(f)
Sources, read November 2026: OSHA 29 CFR 1910.25 · OSHA 29 CFR 1910.28 · OSHA 29 CFR 1910.29 · OSHA 29 CFR 1910.23 · 2021 IBC Table 1607.1, via UpCodes (Texas) · City of Fort Worth, Building & Energy Codes